Initial commit
This commit is contained in:
252
appdata/mqtt-exporter/metrics.yaml
Normal file
252
appdata/mqtt-exporter/metrics.yaml
Normal file
@@ -0,0 +1,252 @@
|
||||
# Example metric definition
|
||||
metrics:
|
||||
- name: 'mhi_ac_ctrl_f_mode'
|
||||
help: 'Mode'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/Mode'
|
||||
label_configs:
|
||||
- source_labels: [ '__value__' ]
|
||||
regex: '^(.*)$'
|
||||
target_label: 'state'
|
||||
replacement: '\1'
|
||||
action: 'replace'
|
||||
- source_labels: [ '__value__' ]
|
||||
replacement: '1'
|
||||
target_label: '__value__'
|
||||
action: 'replace'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_power'
|
||||
help: 'Power'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/Power'
|
||||
label_configs:
|
||||
- source_labels: [ '__value__' ]
|
||||
regex: '^(.*)$'
|
||||
target_label: 'state'
|
||||
replacement: '\1'
|
||||
action: 'replace'
|
||||
- source_labels: [ '__value__' ]
|
||||
replacement: '1'
|
||||
target_label: '__value__'
|
||||
action: 'replace'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_troom'
|
||||
help: 'Room measured temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/Troom'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_tsetpoint'
|
||||
help: 'Room setpoint temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/Tsetpoint'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_td'
|
||||
help: 'Discharge Pipe Temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/TD'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_ct'
|
||||
help: 'Current'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/CT'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_tdsh'
|
||||
help: 'Compressor discharge pipe super heat'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/TDSH'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_ou_fanspeed'
|
||||
help: 'Outdoor unit fan speed'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/OU-FANSPEED'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_ou_defrost'
|
||||
help: 'Defrost control on/off'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/DEFROST'
|
||||
label_configs:
|
||||
- source_labels: [ '__value__' ]
|
||||
regex: '^(.*)$'
|
||||
target_label: 'state'
|
||||
replacement: '\1'
|
||||
action: 'replace'
|
||||
- source_labels: [ '__value__' ]
|
||||
replacement: '1'
|
||||
target_label: '__value__'
|
||||
action: 'replace'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_ou_eev1'
|
||||
help: 'Pulse rate of the outdoor unit expansion valve EEVC'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/OU-EEV1'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_tsetpoint'
|
||||
help: 'Set temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/Tsetpoint'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_return_air'
|
||||
help: 'Return air sensor temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/RETURN-AIR'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_thi_r1'
|
||||
help: 'Indoor heat exchanger sensor (on U bend)'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/THI-R1'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_thi_r2'
|
||||
help: 'Indoor heat exchanger sensor (on Capillary)'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/THI-R2'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_thi_r3'
|
||||
help: 'Indoor heat exchanger sensor (on suction header) '
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/THI-R3'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_iu_fanspeed'
|
||||
help: 'Indoor unit fan speed'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/IU-FANSPEED'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_outdoor'
|
||||
help: 'Outdoor air temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/OUTDOOR'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_tho_r1'
|
||||
help: 'Outdoor unit heat exchanger sensor'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/THO-R1'
|
||||
|
||||
- name: 'mhi_ac_ctrl_f_opdata_comp'
|
||||
help: 'Compressor frequency'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-F/OpData/COMP'
|
||||
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_mode'
|
||||
help: 'Mode'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/Mode'
|
||||
label_configs:
|
||||
- source_labels: [ '__value__' ]
|
||||
regex: '^(.*)$'
|
||||
target_label: 'state'
|
||||
replacement: '\1'
|
||||
action: 'replace'
|
||||
- source_labels: [ '__value__' ]
|
||||
replacement: '1'
|
||||
target_label: '__value__'
|
||||
action: 'replace'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_power'
|
||||
help: 'Power'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/Power'
|
||||
label_configs:
|
||||
- source_labels: [ '__value__' ]
|
||||
regex: '^(.*)$'
|
||||
target_label: 'state'
|
||||
replacement: '\1'
|
||||
action: 'replace'
|
||||
- source_labels: [ '__value__' ]
|
||||
replacement: '1'
|
||||
target_label: '__value__'
|
||||
action: 'replace'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_troom'
|
||||
help: 'Room measured temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/Troom'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_tsetpoint'
|
||||
help: 'Room setpoint temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/Tsetpoint'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_td'
|
||||
help: 'Discharge Pipe Temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/TD'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_ct'
|
||||
help: 'Current'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/CT'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_tdsh'
|
||||
help: 'Compressor discharge pipe super heat'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/TDSH'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_ou_fanspeed'
|
||||
help: 'Outdoor unit fan speed'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/OU-FANSPEED'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_ou_defrost'
|
||||
help: 'Defrost control on/off'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/DEFROST'
|
||||
label_configs:
|
||||
- source_labels: [ '__value__' ]
|
||||
regex: '^(.*)$'
|
||||
target_label: 'state'
|
||||
replacement: '\1'
|
||||
action: 'replace'
|
||||
- source_labels: [ '__value__' ]
|
||||
replacement: '1'
|
||||
target_label: '__value__'
|
||||
action: 'replace'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_ou_eev1'
|
||||
help: 'Pulse rate of the outdoor unit expansion valve EEVC'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/OU-EEV1'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_tsetpoint'
|
||||
help: 'Set temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/Tsetpoint'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_return_air'
|
||||
help: 'Return air sensor temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/RETURN-AIR'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_thi_r1'
|
||||
help: 'Indoor heat exchanger sensor (on U bend)'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/THI-R1'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_thi_r2'
|
||||
help: 'Indoor heat exchanger sensor (on Capillary)'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/THI-R2'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_thi_r3'
|
||||
help: 'Indoor heat exchanger sensor (on suction header) '
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/THI-R3'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_iu_fanspeed'
|
||||
help: 'Indoor unit fan speed'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/IU-FANSPEED'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_outdoor'
|
||||
help: 'Outdoor air temperature'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/OUTDOOR'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_tho_r1'
|
||||
help: 'Outdoor unit heat exchanger sensor'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/THO-R1'
|
||||
|
||||
- name: 'mhi_ac_ctrl_b_opdata_comp'
|
||||
help: 'Compressor frequency'
|
||||
type: 'gauge'
|
||||
topic: 'MHI-AC-Ctrl-B/OpData/COMP'
|
||||
Reference in New Issue